MS LAB
MS LAB

MPW refrigerated and heated laboratory centrifuges

MPW refrigerated and heated laboratory centrifuges

 

Reliable, European-made centrifuges for professional laboratory use.

MPW Med. Instruments is one of Europe's leading centrifuge manufacturers, offering laboratory equipment developed and manufactured in-house for clinical, research and industrial applications. The company's entire production process—from design to manufacturing—is carried out in-house, ensuring continuous quality control and high technical standards.

Modern manufacturing technologies, decades of professional expertise and development based on user feedback together ensure that MPW centrifuges provide a reliable, precise and consistently stable solution for laboratory workflows.

Selected MPW centrifuge models are available in refrigerated and heated versions with a controlled temperature range, ensuring a stable thermal environment for samples during centrifugation.

Depending on the configuration, the models can operate across ranges of up to -20 °C to +40 °C / +55 °C.

Model overview:

Feature Model General features Typical applications
S-Line Compact benchtop centrifuges, easy to operate, lower capacity (maximum capacity: 120 ml) Teaching laboratories, basic clinical testing and routine tasks
M-Line Universal laboratory centrifuges, wide rotor selection and higher performance (maximum capacity: 500 ml) Clinical and diagnostic laboratories, microbiology, QC and the food industry
L-Line Refrigerated and heated centrifuges with a wide operating temperature range for high-performance laboratory applications (maximum capacity: 1 000 ml) Molecular biology, pharmaceuticals and biotechnology
XL-Line High RCF and large volume for industrial and research applications (maximum capacity: 3 000 ml) Pharmaceutical industry, research institutes and high-volume laboratories

Contact us, and we will help you choose!

A wide range of rotor configurations is available for MPW centrifuges, including fixed-angle rotors, swing-out rotors and various reduction adapters. The rotors are compatible with a wide range of tube types, although the complete selection is not listed on this page.

We will be pleased to assist you in selecting the appropriate configuration.

Available models in detail:

MPW S-Line models

Feature Model MPW-54 MPW-55 MPW-56 MPW-150R
Max. capacity 120 ml 48 ml 120 ml 90 ml
Max. RCF/max. RPM 3 122 x g**/ 5 800*** 15 279 x g/ 14 500 3 341 x g/ 6 000 21 382 x g/ 15 000
Refrigeration/heating – – – -20°C – +40°C
Number of rotor configurations (fixed-angle/swing-out rotor)* 3/0 2/1 4/0 7/1
Automatic rotor recognition – – – Yes
Number of user programs (qty.) – 9 – 100

*: The value indicates the number of different rotor configurations (fixed-angle and/or swing-out rotors) available for the respective model.

**: Two maximum relative centrifugal force (RCF) values are available for the specified models (e.g. 1 137 or 3 122 × g)

***: Two maximum speeds (RPM) are available for the specified models (e.g. 3 500 or 5 800 rpm)

MPW M-Line models

Feature Model M-BASIC M-UNIVERSAL M-DIAGNOSTIC** M-SCIENCE MPW-260 MPW-260R MPW-260RH
Max. capacity 120 ml / PRP 500 ml 500 ml 100 ml 500 ml 500 ml 500 ml
Max. RCF/max. RPM 2 469 x g/4 000 24 270 x g/ 18 000 4 830 x g/ 6 000 24 270 x g/ 18 000 24 270 x g/ 18 000 24 270 x g/ 18 000 24 270 x g/ 18 000
Refrigeration/heating – – – – – -20°C – +40°C -20°C – +55°C
Number of rotor configurations (fixed-angle/swing-out rotor)* 1/1 18/4 8/4 8/1 18/3 18/3 18/3
Automatic rotor recognition – Yes Yes Yes Yes Yes Yes
Number of user programs (qty.) 5 100 100 100 100 100 100

*: The value indicates the number of different rotor configurations (fixed-angle and/or swing-out rotors) available for the respective model.

**: Cyto version: for cytology applications (gentle separation and processing of cells)

MPW L-Line models

Feature Model MPW-351e MPW-352** MPW-352R** MPW-352RH**
Max. capacity 800 ml 1 000 ml 1 000 ml 1 000 ml
Max. RCF/max. RPM 3 600 x g/4 500 24 270 x g/18 000 30 065 x g/18 000 30 065 x g/18 000
Refrigeration/heating – – -20°C – +40°C -20°C – +55°C
Number of rotor configurations (fixed-angle/swing-out rotor)* 3/2 24/7 24/7 24/7
Automatic rotor recognition – Yes Yes Yes
Number of user programs (qty.) 5 100 100 100

*: The value indicates the number of different rotor configurations (fixed-angle and/or swing-out rotors) available for the respective model.

**: Cyto version: for cytology applications (gentle separation and processing of cells)

MPW XL-Line models

Feature Model MPW-380 MPW-380R
Max. capacity 3 000 ml 3 000 ml
Max. RCF/max. RPM 31 876 x g/18 000 31 876 x g/18 000
Refrigeration/heating – -20°C – +40°C
Number of rotor configurations (fixed-angle/swing-out rotor)* 14/6 16/6
Automatic rotor recognition Yes Yes
Number of user programs (qty.) 100 100

*: The value indicates the number of different rotor configurations (fixed-angle and/or swing-out rotors) available for the respective model.

 

Life Science syringes

Life Science syringes

 

Life Science syringes – precise solutions for biological and research applications

Hamilton Life Science syringes offer solutions specifically developed for biological, medical and research applications where accurate microvolume dispensing, minimal sample loss and reproducibility are critical.

From neuroscience syringes to specialised connection and gel-loading solutions, the range meets the needs of modern life science laboratories.

View the detailed product catalogue

Neuros syringes – for neuroscience and animal research applications

Hamilton Neuros syringes enable controlled, precise injection in neuroscience and animal research environments while minimising tissue damage.

Key features:

  • dispensing range from 50 nL to 100 µL
  • ultra-thin, fine-gauge needles
  • adjustable needle extension (0–20 mm)
  • low dead volume and excellent repeatability
  • compatible with stereotaxic holders and infusion pumps

Spare parts, needles, adapters and sleeves are also available for the system, ensuring cost-effective long-term use.

Syringes for various connections and tubing systems

Syringes for connection to fine-gauge needles

Solutions with exceptionally low dead volume for syringes with RN connections, primarily for volumes below 100 µL.

Glass micro pipettes

Ideal for neuroscience applications, with an extremely fine tip:

  • precise tissue penetration
  • minimised tissue damage
  • quick and secure connection with an RN compression fitting

PE and PEEK tubing solutions

PE tubing: simple, quick connection for animal research

PEEK tubing: excellent chemical resistance, low dead volume and high pressure resistance

Can be securely connected to RN syringes using compression fittings

Priming Kit – efficient priming for low volumes

The Hamilton Priming Kit provides a solution for the difficult priming of low-volume systems:

  • reduces air-bubble formation
  • facilitates the priming of tubing and syringes
  • particularly recommended for sensitive life science and neuroscience applications

Specialty syringes (Specialty Syringes)

Threaded plunger syringes– Threaded Plunger Syringes

Rotating the plunger enables exceptionally fine, controlled volume dispensing.

  • Ideal for manual microdispensing
  • Stable, reproducible setting
  • Compatible with Luer and RN connections

Gel-Loading syringes – for molecular biology applications

Gel-Loading syringes are specifically designed for DNA/RNA electrophoresis.

Benefits:

  • rapid and accurate sample dispensing
  • fixed and adjustable versions
  • multi-channel versions
  • optimised needle spacing for 96-well plates

An ideal choice for routine and high-throughput molecular biology workflows.

Micro Syringe Pipette – for specialised samples

The Micro Syringe Pipette is suitable for handling samples that are incompatible with conventional pipette tips.

Features:

  • disposable PTFE tips
  • minimal cross-contamination
  • 0.2–3 µL volume range
  • excellent volume reproducibility

 

TLC and TOC Syringes – For Special Applications

TLC and TOC Syringes – For Special Applications

 

Hamilton special-purpose syringes are designed for applications where sample application accuracy, repeatability and system compatibility are critical.

These include syringes developed for thin-layer chromatography (TLC) and TOC systems, whose design differs significantly from conventional GC or HPLC solutions.

View the detailed product catalogue

Thin-Layer Chromatography (TLC) Syringes– Thin-Layer Chromatography Syringes

Hamilton TLC syringes are specifically designed for thin-layer chromatography applications, where precise and reproducible sample spotting is essential.

The first 19 mm of the needle has a PTFE coating that reduces surface tension between the needle and the liquid. This ensures stable droplet formation and enables uniform, controlled sample application onto TLC plates.

Key features:

  • PTFE coating on the needle tip for consistent droplet formation
  • excellent reproducibility during TLC spotting
  • accurate, controlled sample application
  • suitable for routine and research TLC applications

Available designs:

  • Cemented-needle (N) TLC syringes
  • Removable-needle (RN) TLC syringes, where the TLC needle can be fitted to the syringe as a standard removable needle

TLC syringes are available in multiple volume and needle-diameter options, making them easy to adapt to the specific analytical method and sample requirements.

Typical applications:

  • Spotting samples onto TLC plates
  • separation of organic compounds
  • rapid qualitative and quantitative analyses

TOC syringes– Carbon Analyzer Syringes

Hamilton Carbon Analyzer syringes are specifically designed for TOC (Total Organic Carbon) analysers and water analysis applications where accurate sample introduction and a system-compatible connection are essential.

These syringes feature a special cemented connection that provides a precise, secure fit to the carbon analyser inlet. The design minimises dead volume and maintains consistent measurement accuracy.

Key features:

  • special cemented connection on the syringe barrel
  • tapered Luer-style connector for stable sample introduction

The plunger and syringe barrel are not interchangeable, ensuring long-term measurement stability.

Applications:

  • TOC analysers
  • drinking water analysis
  • environmental analysis
  • laboratory water quality control

Precise mechanical fit and robust materials ensure reliable, long-lasting operation, even in demanding laboratory environments.

 

Manual and Autosampler GC Syringes

Manual and Autosampler GC Syringes

 

Manual and Autosampler GC Syringes – Hamilton Solutions for Gas Chromatography

Hamilton GC syringes are among the most critical components of sample introduction in gas chromatography. Accurate volume dispensing, minimal wear on the injector and septum, and a long service life are essential for both manual and automated GC systems.

Our website presents the most common GC syringe types and compatibility options, and we can help you select the right custom configuration.

View the detailed product catalogue

Manual GC Syringes (Manual GC Syringes)

Standard GC Syringes

Volume range: 0.5 µL – 500 µL

Standard GC syringes are designed for split and splitless injectors. Non-coring needles reduce septum damage while ensuring consistent, repeatable sample introduction.

Available designs:

  • Knurled Hub (KH)
  • Cemented needle (N)
  • Luer Tip cemented needle (LTN)
  • Removable-needle design (RN)

Recommended applications:

  • Routine GC analysis
  • Organic solvents and volatile compounds

Purge and Trap GC Syringes

Volume: 5 mL and 25 mL

Syringes specifically designed for purge & trap applications, with a removable plunger for easier sample loading.

Typical applications:

  • Drinking water and environmental analysis
  • EPA purge & trap methods (e.g. 502.1, 503.1, 524.1, 524.2)

The robust mechanical design ensures a long service life even under heavy use.

SampleLock GC Syringes

Volume range: 50 µL – 100 mL

The SampleLock system enables samples to be collected, transported and dispensed safely without evaporative loss.

Benefits:

  • Suitable for both gas and liquid samples
  • Positive-locking plunger
  • Minimised evaporation and environmental contamination
  • Broad connectivity with different valves

On-Column GC Syringes

Volume: 0.5 µL and 10 µL

On-column injection introduces the sample directly into the capillary column, avoiding thermal stress.

Ideal for:

  • Thermally sensitive compounds
  • Low-boiling-point samples
  • Measurements requiring high analytical accuracy

The long, fine-diameter needle enables precise positioning.

GC Autosampler Syringes (GC Autosampler Syringes)

Hamilton GC autosampler syringes are designed for automated sample introduction, where reproducibility, cycle life and a precise fit are essential.

Agilent GC Autosampler Syringes

Compatible systems:

  • 7670, 7671, 7672 ALS
  • 7683, 7693 ALS

Available designs:

  • Cemented needle (N)
  • Removable needle (RN)

Special connections

The design optimised for Agilent ALS systems ensures a long service life and consistent injection accuracy.

Bruker / Varian GC Autosampler Syringes

Compatible systems:

  • 8100, 8200
  • CP-8400, CP-8410
  • CP-9010/9050
  • CP-9020/9025

Special-connection and cemented-needle designs for stable and reliable sample introduction.

CTC / LEAP PAL GC and Headspace Syringes

Syringes available for CTC PAL systems:

  • S-Line syringes – cost-effective solutions for general GC applications
  • C-Line syringes – reduced sample-transfer loss
  • HD-Type and HDHT-Type syringes – for high-temperature headspace applications (up to 200 °C)

Special plunger and sealing solutions ensure reliable sealing performance and a long service life.

GC Autosampler Compatibility with Other Manufacturers

Hamilton syringes are available for the following systems:

  • Shimadzu (AOC-9, AOC-14, AOC-17, AOC-20)
  • Thermo Finnigan (AI/AS 3000, AS 800/2000, HS 250/500/850)
  • PerkinElmer (AutoSystem, Clarus GC)
  • Waters GC systems

 

Manual HPLC Syringes and HPLC Autosampler Syringes

Manual HPLC Syringes and HPLC Autosampler Syringes

 

Hamilton HPLC syringes are among the most critical components of high-performance liquid chromatography (HPLC) systems. Whether for manual injection or automated sample introduction, selecting the right syringe is essential for accurate, reproducible and reliable long-term measurements.

Our website presents the most commonly used manual HPLC syringes and autosampler-compatible HPLC syringes.

View the detailed product catalogue

We can always help you select the specific catalogue numbers and configurations and provide a customised quotation.

Manual HPLC Syringes

Hamilton manual HPLC syringes are specifically designed for high-pressure injection. Their specially designed needle geometry and surface treatment reduce wear on valves and seals while ensuring accurate injection volumes.

Rheodyne, Valco, Beckman and SSI Valves

Volume range: 2.5 µL – 1 mL

These syringes are compatible with the most widely used manual HPLC injection valves.

Features:

  • cemented needle, Luer Tip or removable-needle design
  • stable, accurate volume dispensing
  • for conventional HPLC injection applications

An ideal choice for routine analytical measurements and validated methods.

Constant Rate Syringes

Volume range: 20 µL – 200 µL

Constant Rate syringes provide a preset, constant injection rate.

Benefits:

  • excellent reproducibility
  • volume adjustment with micrometre precision
  • ideal where injection rate is a critical parameter

Valco VISF-1 Injection Valves

Volume range: 25 µL – 10 mL

Manual HPLC syringes specifically designed for Valco VISF-1 valves.

Key features:

  • precise fit with the valve
  • also suitable for larger-volume injections
  • reliable sealing at high pressure

Waters Manual HPLC Syringes

Volume range: 10 µL – 250 µL

Hamilton syringes compatible with Waters HPLC systems feature optimised connections and needle designs.

Applications:

  • Waters U6K and other manual injection valves
  • accurate injection and long service life

HPLC Autosampler Syringes

HPLC autosampler syringes are designed for automated sample introduction. Their instrument-specific design ensures a precise fit, minimal dead volume and a long cycle life.

General features:

  • needle length and point style optimised for autosamplers
  • reduced wear on valves and seals
  • stable, reproducible sampling for large sample batches

Available autosampler compatibility:

  • Agilent, Shimadzu, Waters
  • Thermo Finnigan, PerkinElmer
  • Varian, Dionex, CTC / LEAP PAL systems
  • Spark Holland autosamplers
  • Hitachi LaChrom systems
  • Kontron HPLC systems

Each autosampler syringe is optimised for the specific instrument, ensuring accurate operation and a long service life.

 

Hamilton Syringes – General Laboratory Use

Hamilton Syringes – General Laboratory Use

 

Hamilton is one of the world's best-known and most trusted manufacturers in the precision laboratory syringe market.

Its products are used in analytical, research, industrial and life science laboratories, for dispensing volumes ranging from a few microlitres to several litres.

Our website presents the most commonly used Hamilton syringe ranges and their applications.

We provide expert assistance and a customised quotation to help you select the exact configuration (volume, needle type, connection and design).

View the detailed product catalogue

Available Hamilton Syringe Types

Microliter Syringes– Hamilton Microliter Syringes

Syringes specifically designed for precise liquid dispensing at very low volumes.

Ideal for homogeneous samples where accuracy and repeatability are especially important.

Key features:

  • stainless steel plunger
  • precision-machined glass syringe barrel
  • minimal dead volume
  • excellent repeatability and long service life

Available series:

  • 600 Series – 2.5 µL – 5 µL
  • 700 Series – 5 µL – 500 µL
  • 800 Series – 5 µL – 250 µL (reinforced plunger design)
  • 7000 Series – 0.5 µL – 5 µL (modified Microliter design for ultra-low volumes)

Gastight Syringes– Hamilton Gastight Syringes

Leak-free syringes suitable for dispensing both liquids and gases.

Especially recommended for heterogeneous samples, volatile components and gas analysis.

Key features:

  • PTFE or special polymer plunger tip
  • excellent sealing performance
  • reduced deposits and plunger seizure
  • liquid and gas dispensing with a single device

Available series:

  • 1700 Series – 10 µL – 500 µL
  • 1800 Series – 10 µL – 250 µL (reinforced design for low volumes)
  • 1000 Series – 1 mL – 100 mL
  • Super Syringes – 500 mL – 2 L

Digital Syringes– Hamilton Digital Syringes

A modern solution that displays the dispensed volume on a digital screen.

Especially useful when visual reading errors are unacceptable.

Benefits:

  • elimination of parallax error
  • greater dispensing accuracy
  • easily reproducible measurement results
  • manual operation with digital readout

Calibrated Syringes– Calibrated Syringes

Factory-calibrated Hamilton syringes supplied with a certificate for quality-assured measurements.

Features:

  • NIST-traceable calibration
  • documented accuracy
  • certificate supplied with the product
  • ideal for validated and audited laboratory environments

Luer, Luer Lock and Syringes with Special Connections

These syringes are specifically designed for connection to external systems where conventional manual dispensing is not used.

Typical applications:

  • syringe pumps
  • tubing systems (PE, PEEK tubing)
  • automated dispensing and sample-handling systems
  • laboratory and industrial fluid-transfer solutions

Key features:

  • Luer or Luer Lock connection
  • low dead volume
  • secure, leak-free fit
  • compatibility with Hamilton RN and special adapter solutions

These syringes are ideal for applications requiring repeatable, controlled liquid dispensing in manual or automated environments.

Digital and Calibrated Syringes – Combined Solutions

Some laboratory environments require dispensing volumes to be digitally readable while measurements are performed with certified accuracy.

Digital and factory-calibrated Hamilton syringes provide a solution for these requirements.

Benefits:

  • digital display for accurate volume readings
  • NIST-traceable calibration
  • documented measurement accuracy
  • suitable for use in audited, validated laboratory environments

Recommended applications:

  • quality control laboratories
  • validated analytical methods
  • regulated industrial and pharmaceutical environments
  • research and development applications

Large-Volume Syringes (Super Syringes)

Hamilton large-volume syringes provide reliable and accurate dispensing above 500 mL, where conventional syringes are no longer suitable.

Typical applications:

  • industrial sampling
  • validation and calibration tasks
  • gas and liquid storage and dispensing
  • teaching and demonstration purposes

Key features:

  • large volume: 500 mL – 2 L
  • robust design
  • gastight construction
  • acrylic syringe barrel for greater mechanical stability

 

Restek GC Columns and Accessories

Restek GC Columns and Accessories

 

Restek GC columns and accessories – gas-chromatography solutions

Restek gas-chromatography (GC) columns are recognised worldwide for their outstanding reproducibility, long service life and application-specific solutions.

Our portfolio covers GC applications ranging from routine analysis to complex, regulated methods (EPA, USP, ISO).

Restek– GC column portfolio

Analytical GC capillary columns

A wide selection of conventional fused-silica capillary columns for general and targeted analytical applications.

Typical phases and types:

  • non-polar and low-polarity columns
  • medium- and high-polarity phases
  • general-purpose columns for routine analyses

Applications:

  • VOC, SVOC
  • solvents
  • hydrocarbons
  • volatile organic compounds

Specialised GC columns for target analytes

For applications where selectivity is critical and standard columns do not provide adequate separation.

Typical analyte groups:

  • nitrosamines
  • pesticides
  • PAHs, phthalates
  • sulfur- and nitrogen-containing compounds
  • explosives, active pharmaceutical ingredients

GC columns for environmental and food analysis

Columns developed specifically for standardised methods.

Typical applications:

  • drinking-water and soil analysis
  • food safety
  • mineral-oil fractions
  • biodiesel, FAME
  • MCPD, MOSH/MOAH

Chiral GC columns

Columns optimised for separating the enantiomers of optically active compounds.

Applications:

  • pharmaceutical chiral analysis
  • flavours and fragrances
  • biologically active components
  • GC PLOT and packed columns
  • For analysing gaseous or highly volatile components

Typical applications:

  • light hydrocarbons
  • permanent gases
  • residual solvents

Available Restek GC Accessories and Consumables

Restek not only offers comprehensive GC column solutions, but also provides compatible, reliable accessories and consumables for every critical point in gas-chromatography systems.

These components play a key role in stable operation, signal quality and reproducibility.

GC inlet accessories

Injection quality fundamentally determines measurement results.

Available product types:

  • inlet liners (for various geometries and applications)
  • septa
  • inlet liner seals
  • inlet seals
  • nuts and plugs
  • GC inlet tools

GC detector accessories

Reliable operation with various detector types.

Supported detectors:

  • MS (mass spectrometer)
  • FID, ECD, PID
  • methaniser systems

Accessories:

  • detector-specific consumables
  • seals and connectors
  • components supporting sensitivity and signal stability

Gas purification and gas-generator solutions

The purity of the carrier and auxiliary gases is critical in GC systems.

Available solutions:

  • replaceable gas filters
  • complete gas filter kits
  • gas generators
  • baseplates
  • connectors and O-rings

Ferrules, fittings and connectors

Secure, leak-free connections even at high temperatures and pressures.

Product ranges:

  • ferrules, fittings, connectors
  • fitting kits

Instrument Accessories and Tools

For efficient maintenance and troubleshooting.

Available tools:

  • leak detectors
  • flow meters
  • tool kits
  • GC oven accessories
  • autosampler accessories
  • inlet maintenance kits
  • split vent traps

Tubing and Pressure Regulation

A stable gas supply is essential for accurate GC analysis.

Solutions:

  • tubing in various materials
  • pressure regulators
  • tube-working tools

 

Restek HPLC Columns and Accessories

Restek HPLC Columns and Accessories

 

Restek HPLC columns and accessories – comprehensive solutions from a single source

Restek is known worldwide for its highly reliable chromatography products. In addition to HPLC columns, it offers a comprehensive portfolio of LC accessories covering every critical component of liquid-chromatography systems – from autosamplers and detectors to pumps.

Restek – LC Column Portfolio

Analytical LC columns

  • C18, C8, C4, C1
  • Biphenyl, Phenyl-Hexyl, Fluorophenyl, PFP (Pentafluorophenyl)
  • Silica, Cyano, Amino

HILIC columns

  • HILIC-Si, Amino-HILIC
  • Polar-embedded phases
  • Mixed-mode HILIC columns

Preparative LC columns

  • Preparative C18 columns
  • Preparative C8 columns
  • Preparative HILIC columns
  • Large-internal-diameter silica columns
  • Columns optimised for fraction collection

LC–MS columns

  • LC–MS-compatible C18 columns
  • MS-friendly HILIC columns
  • Small-particle (sub-2 µm) columns
  • Columns designed for rapid gradient analysis

Guard columns

  • Guard cartridges
  • Guard-column holders
  • Replaceable guard inserts
  • Guard solutions matched to analytical columns

Specialised LC columns

  • Aromatic-selective columns (PAHs, isomers)
  • Mixed-mode columns
  • Ion-pair-compatible columns
  • Polar-embedded-phase columns
  • Specialty columns developed for specific applications

Available Restek LC accessories and consumables

Restek's HPLC portfolio covers the key accessories required to operate and maintain liquid-chromatography systems. Our range includes all the following product categories:

LC autosampler accessories

  • autosampler needle assemblies
  • sample loops
  • rotor seals
  • seal kits

LC pump accessories

  • cartridges, diaphragms
  • filters and frits
  • O-rings, lubricants

LC detector accessories

  • deuterium lamps
  • detector consumables

LC tubing and fitting systems

  • stainless-steel and PEEK tubing
  • connectors, elbows, manifolds
  • high-pressure fittings

Mobile-phase handling and LC system accessories

  • solvent bottles and caps
  • degassers
  • mixers, flow splitters
  • column heaters

LC–MS accessories

  • electrodes
  • solutions for nitrogen generators

Maintenance and organisation solutions

  • maintenance kits
  • tools
  • organisation solutions

 

Hamilton HPLC Guard Columns

Hamilton HPLC Guard Columns

 

HPLC guard columns (precolumns)

Hamilton guard columns have a modular design, and cartridges can be replaced quickly without tools, minimising downtime.

Key benefits:

  • protects the analytical column from clogging and irreversible contamination
  • reduces column replacement costs
  • minimises band broadening caused by additional dead volume

Available configurations:

  • stainless-steel and PEEK cartridge holders for analytical applications
  • stainless-steel semi-preparative and preparative holders
  • compatible with Hamilton PRP, RCX, HC and ion-chromatography column families

Detailed specifications and compatible models are available in the manufacturer's catalogue, which also offers targeted search options.

Download the detailed product catalogue

Get in touch, and we will help you choose!

 

Hamilton Ion-Exclusion HPLC Columns

Hamilton Ion-Exclusion HPLC Columns

 

Ion-exclusion chromatography columns (Ion Exclusion Columns)

Hamilton PRP-X300 ion-exclusion HPLC columns

The PRP-X300 is a versatile, high-performance ion-exclusion column developed for the rapid separation of structurally similar organic acids and alcohols.

The column operates through a combination of separation mechanisms:

  • ion exclusion
  • hydrogen bonding
  • reversed-phase interactions

As a result, the PRP-X300 can also be used effectively for samples that would show excessive retention on conventional ion-exclusion media.

Key features and benefits

  • Polymer-based PS-DVB/sulfonic acid packing with excellent chemical stability
  • Isocratic separation with narrow, well-defined peaks
  • Selectivity can be finely controlled by adjusting the pH or adding organic modifiers (e.g. methanol or acetonitrile)
  • Resistant to organic solvents, allowing a wider range of sample matrices to be handled

Configurations and available formats

PRP-X300 columns are available:

  • in stainless-steel and PEEK configurations
  • in various column lengths and diameters
  • in analytical and semi-preparative dimensions
  • with guard columns and guard cartridge systems
  • as bulk resin for method development

Extensive range – catalogue-based search

Ion-exclusion HPLC columns are available in numerous dimensions, particle sizes and configurations, so the complete range is not listed individually on this page.

Download the detailed product catalogue

Get in touch, and we will help you choose!

 

MS LAB

MS Lab Pro Kft. offers reliable laboratory solutions and a carefully selected brand portfolio. Fast quotations, expert support and flexible procurement.

Newsletter subscription

Subscribe to our newsletter to be among the first to hear about our latest developments.

© 2026 MS Lab Pro Kft. All rights reserved